Description
Standard options include:
Electronic measurement and flow control of N2, NH3, dissociated NH3 (DA), CO2, CO, endothermic gas, H2, N2O, H2O. |
Measurement, control, and/or alarming of O2, H2, %DA, Kc, Kn, Pre/post oxidation. |
Programmable furnace control of entire process (single and multi-stage processes) |
Precise control of compound layer |
Automatic alarm and safety features including O2 monitoring and N2 emergency purge |
Sophisticated alarm system for nitriding atmosphere, gas flow, pressure, temperature deviation from set points. |
Touch screen, configurable HMI with chart recorder/data logging. AMS 2750 E compliance. |
Furnace electrical power control for multiple zones including thyristors, fusing, disconnects, CTs. |
Complete control cabinet or backplate for retrofit of existing cabinet (assuming existing cabinet meets or can be upgraded to meet current CE requirements). |